Product Description
The CloudGate Probe is a compact, DIN rail-mountable metering device designed to connect various devices over Modbus (RS-485), M-bus, Digital & Analog Inputs to a Cellular (NB-IoT/LTECatM) network. This enables convenient remote monitoring of assets and buildings.
As a cost-effective and compact solution, the CloudGate Probe is capable of reading and transmitting data from nearly any meter to any IoT platform. Additionally, it can be used to adjust settings or control the state of actuators such as HVAC systems, control valves, relays, and more.
The CloudGate Probe Cellular is ideal for asset monitoring use cases.
Data Sheet
The English datasheet, titled Option_CloudGateProbe_NB-IoT_Datasheet.pdf is available for download at the bottom of this page.
Configuration Options
The CloudGate Probe can be configured in three different ways:
- MQTT
- Programming Cable and Command Line Interface (CLI) Tool
- Factory Configuration (Available for bulk orders, subject to Minimum Order Quantity)
For this option, please fill in the CloudGate Probe Cellular Configuration Request Form at the bottom of this page and contact [email protected] or your sales contact.
We recommend configuring your CloudGate Probe devices via MQTT for ease of use. The CLI tool for manual configuration is available for download below. For larger projects, we offer factory pre-configuration services. Please contact your local representative for more information.
Recommended Hardware
For RS-485 configuration, we recommend using the following USB to RS485 dongle, which is the model we use internally: DFRobot FIT0737 USB to RS485 Dongle
Technical Information
The CloudGate Probe has the following capabilities.
Cellular modem:
- LTE Cat M1 / Cat NB2
- Supports EU frequency bands B3, B8, and B20
- International coverage available on demand
- Integrated GNSS receiver for positioning
- Two external antenna connectors (SMA)
M-Bus Mini-Master:
- 34V bus power supply
- Supports up to 4 Unit Loads
- Screw terminal connection
Modbus Interface:
- RS485 communication
- Half-duplex operation
- Screw terminal connection
Analog Input (A-IN) Configurable Options:
- 0-3.3V input conversion
- 0-10V input conversion
- 4-20mA input conversion
Digital Input (D-IN) Configurable Options:
- CMOS input: 0-3.3V
- Dry contact input
- S0 pulse-counter
Analog Output (10V) (20mA):
- 0-10V output with ±0.01V precision
- 4-20mA output with ±1% precision
Digital Output (D-OUT) Configurable Options:
- CMOS output: 0-3.3V
- Open Drain output (<250mA)
Optional Last-Gasp Backup Power
- Provides more than 10 seconds of operation after a power outage